T-10A/T-10MA meets the requirements of JIS AA level and DIN B level illuminometer, and is compatible with the new generation light source including PWM control light source. Main application Official testing agency Research and testing of lighting manufac

Commodity details

T-10A/T-10MA meets the requirements of JIS AA level and DIN B level illuminometer, and is compatible with the new generation light source including PWM control light source.

Main application
Official testing agency
Research and testing of lighting manufacturers
Maintenance in factories, offices, hospitals, etc.
Illumination control for safety lighting and street lighting
Detection of building light source
Lighting control of LED lighting workshop
Sensors for measuring devices such as luminous flux or light intensity distribution

Main specifications

ModelIlluminance meter T-10A
 
Illuminance meter T-10MA
 
Illuminance meter T-10WsA
 
Illuminance meter T-10W L A
 
typeMulti function digital illuminometer with detachable probe (up to 2-30 points for multi-point measurement)
Illuminance levelIn accordance with JIS C 1609-1:2006 AA level, the requirements of "first general measuring instruments" of illuminometer are in line with DIN 5032 seventh section B level.Conforming to the requirements of JIS C 1609-1:2006 for special illuminance meter One
sensorSilicon photocell
Correlation spectral sensitivityCIE spectral luminous efficiency V (lambda) deviation 6% (f1') below
Cosine correction property (f) Two )Less than 3%Less than 10%
measuring rangeAutomatic range conversion (analog output can manually transform 5 ranges).
Measuring functionIlluminance (LX); illuminance difference (LX); illuminance ratio (%); integral illuminance (LX. H); integral time (H); average illuminance (LX)
measuring rangeillumination0.01 ~ 299900 LX; 0.001 ~ 29990 FCD1 ~ 299900 LX; 0.001 ~ 29990 fcd* Two
Integral illuminance0.01 to 999900 x 10 Three LX. H; 0.001 to 99990 x 10 Three FCD. H / 0.001~9999h
User calibration functionCCF (color correction parameter) setting function: measured value * 0.500~2.000
linearThe value of the display is + 2% + 1 bits.
Temperature / humidity errorLess than 3%
Digital outputUSB
Analog output1mV/ bit, (maximum reading 3V); output impedance: 10K; 90% response time: 28ms
display3 or 4 digit LCD with backlighting (automatic lighting).
Power SupplyTwo AA battery / power adapter AC-A308 (sold separately: for 1-10 probes) or
Power adapter AC-A311 (sold separately: for 1-30 probes)
Battery life72 hours or longer (using alkaline batteries for continuous measurement).
Working temperature / humidity range-10~40 degree C, relative humidity below 85% (35 degree C).
No condensation
5~40 degree C, relative humidity below 85% (35 degree C).
No condensation
Storage temperature / humidity range-20~55 degree C, relative humidity below 85% (35 degree C).
No condensation
0~55 degree C, relative humidity below 85% (35 degree C).
No condensation
size69 x 174 x 35 mmMain engine: 69 x 161.5 x 30 mm
Probe: Phi 16.5 x 13.8 mm
Connection length~1 m5 m10 m
weight
(excluding batteries)
200 g (7 oz.)205 G260 g (probe only:
120 g)
340 g (probe only:
200 g)


*1 meets all project requirements except JIS C 1609-1:2006 AA level except cosine correction characteristic (F2).
*2 can be measured below 1 LX, but it will also cause instability due to the influence of acoustic noise.

* do not touch cables during measurement. This may lead to unstable measurements.
* data lines should be fixed during the measurement period. Failure to do so may lead to instability of measurements.