Setting the Standard for Color Measurement
The eXact Standard spectrophotometer is specifically designed for printers and packaging converters to help ensure color validation of CMYK and spot-color inks and also leverages industry color standards for increased press process control.
Benefits of eXact
Streamline Jobs on Press
- Provides all density metrics plus colorimetric/value functions resulting in better validation of color control
- Supports all industry print standards: G7, ISO, PSO, and Japan Color
Best in Spot Color Support
- Provides enhanced spot color handling by allowing creation and management of standards and color libraries to be located on your device
Enhanced Measurement Capabilities
- Reduces wasted time and materials with simultaneous measurements of M0/M1/M2/M3 conditions
Rising Above the Rest
The eXact family offers a unique density and color measurement experience when compared to other products in the market through several differentiators:
- Protected Automated White Tile Calibration protects the instrument’s accuracy from press room dust at all times. Other instrument’s have exposed white tile calibration that could affect the instruments accuracy in press room environments.
- Consistency is key for brands. eXact has three measurement light sources compared to other instrument’s two. The three sources result in a truly ISO defined circumferential illumination that reduces variation resulting from angular rotation on media with any texture like uncoated stocks or digitally printed media that may have directional printing effects.
- eXact provides the most versatile aperture set. You can meet different workflows needs and patch sizes when compared to other instruments: 1.5mm, 2mm, 4mm, & 6mm. eXact’s 2mm spot size is the most popular by capturing a sufficient number of printed dots but enables good measurement of 3mm patches.
- Lastly, X-Rite provides an end-to-end color management experience with software integration for ink formulation and quality control while providing global service offerings that reduce the risk of workflow downtime.
Aperture | 1.5 mm, 2 mm, 4 mm or 6 mm |
---|---|
Battery |
Lithium Ion, 7.4VDC, 2200mAh |
BestMatch Feature | Yes |
Calibration | Automatic on integrated white reference |
Color Spaces | CIE L*a*b*, CIE L*C*h° |
Color Differences | CIE ∆E* (1976), ∆ECMC, CIE ∆E* (2000), and CIE ∆E* (1994) |
Communication Interface | USB 2.0; Bluetooth (optional) - Class II |
Configuration Options | Bluetooth, NetProfiler |
Density Range | 0.0 D – 3.0 D |
Density Standards | Status A, E, I, T and G |
Dimensions (length, width, height) |
18 cm x 7.8 cm x 7.6 cm 7.1" x 3.1" x 3.0" |
Embedded NetProfiler Support | Yes |
G7 Certification | Yes with embedded G7, PSO, JapanColor job templates |
Humidity | 30 to 85% RH (non-condensing) |
Illuminants | A, C, D50, D55, D65, D75, F2, F7, F11, D12 |
Instrument Display | Color touch-screen, 320 x 240 pixels |
Inter-Instrument Agreement |
Average: 0.25 ΔEab, Max: 0.45 ΔEab (for M3: 0.55 ΔEab) (Measurements using X-Rite manufacturing standards at a temperature of 23°C +/- 1°C, 40-60% RH for all measurement modes on 12 BCRA color tiles and a white ceramic reference (D50, 2°)) |
Languages Supported | Chinese Simplified, Chinese Traditional, Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Slovenian, Spanish, Swedish, Turkish, Vietnamese |
Light Source | Gas filled tungsten (illuminant type A) and UV LED |
Industry Standards | ISO 5-4:2009(E), ISO 13655:2009 |
Measurement Conditions | M0, M1 (part 1), M1 (part 2) , M2, M3; also available in Xp variant for flexible packaging substrates |
Measurement Geometry | 45°/0° ring illumination optics, ISO 5-4:2009(E) |
Measurement Time | < 1 sec |
NetProfiler Support | Yes |
Observers | 2° and 10° |
Operating Temperature Range |
10°C to 35°C 50°F to 95°F |
PantoneLIVE Support | Yes; Embedded Pantone Libraries |
Pass / Fail | Yes |
Sample/Measurement | Max. 5,000 samples |
Short Term Repeatability - White | 0.05 ΔEab (standard deviation) White BCRA (Error compared to mean value of 10 measurements every 5 seconds) |
Short Term Repeatability - Density | '+/- 0.01 D for CMYK (Status E or Status T measurements, maximum error compared to mean value of 10 measurements every 5 seconds at 2.0 D except for M3 Yellow at 1.7 D) |
Software Development Kit |
Yes |
Software Modes | Basic |
Spectral Analyzer | DRS spectral engine |
Spectral Interval | 10 nm |
Spectral Range | 400 nm to 700 nm |
Spectral Reporting | 400 nm to 700 nm with 10 nm interval |
Storage Temperature Range |
-20° to 50°C -4° to 122°F |
Standards | More than 20'000 standards (incl. data for all M modes); New Color Library Tool to Create and Store Standards |
Voltage | 12 VDC @ 2.5 A |
Warranty | 1 year |
Weight |
700 g 1.6 lbs. |
What's Included? | USB cable, power supply, CD with software and documentation, docking/charging station, quick start guide, carrying case, device certificate |
3rd Party Software Supported |
X-Rite ColorCert, X-Rite Color iQC, X-Rite InkFormulation, X-Rite NetProfiler and many others |